Triveni Classic Audiometer

Features and Specifications :
1> Built using completely new DSP technology, for superior performance.
2> Completely click less interrupt.
3> +20dB key.
4> Masking: - Wide, Narrow & Speech band noise.
5> Special Tests:- Tone Decay & Warble Tone.
6> Pulse Tone function.
7> Bone conduction:- 125Hz(40dB), 250Hz(50dB), 500Hz(70dB), 750Hz(70dB), 1Khz(70dB), 1.5Khz(70dB), 2Khz(70dB), 3Khz(70dB), 4Khz(70dB), 6Khz(70dB).
8> Air conduction:- 125Hz(80dB), 250Hz(90dB), 500Hz(120dB), 750Hz(120dB), 1Khz(120dB), 1.5Khz(120dB), 2Khz(120dB), 3Khz(120dB), 4Khz(120dB), 6Khz(100dB), 8Khz(100dB).
9> Provided with Oticon / RadioEar bone vibrator and HD-01 headphones
10> Can be connected to a computer via USB.
11> PC software provided free of cost in standard packing.
12> Possible to connect to free-field Amplifier via separate junction box.
13> Complete digital calibration.

Packing List :
1> Classic Audiometer.
2> HD-01 Headphones standard. (Optional TDH 39/49)
3> Oticon Bone conductor. (Optional RadioEar B71)
4> USB cable for computer connection.
5> External microphone with lapel clip.
6> CD containing Audiometer - Control software.
7> Patient Response Switch
8> Operating Manual.
9> Carry Case

Triveni TAM-25 Audiometer

Features and Specifications :
1> Fully DSP Based Audiometer for excellent performance.
2> Inputs can be SPEEH, PURE TONE, WARBLE TONE.
3> Completely click less interrupt.
4> +10dB key.
5> Masking: - Wide, Narrow & Speech band noise.
6> Dedicated L-R toggle key.
7> Bone conduction:- 250Hz(50dB), 500Hz(70dB), 750Hz(70dB), 1Khz(70dB), 1.5Khz(70dB), 2Khz(70dB), 3Khz(70dB), 4Khz(70dB), 6Khz(70dB).
8> Air conduction:- 250Hz(90dB), 500Hz(120dB), 750Hz(120dB), 1Khz(120dB), 1.5Khz(120dB), 2Khz(120dB), 3Khz(120dB), 4Khz(120dB), 6Khz(100dB), 8Khz(100dB).
9> Provided with Oticon A20 bone vibrator and HD-01 headphones.
10>Complete digital calibration.
11>Can be connected to a computer via USB port.
12> PC software provided free of cost in standard packing.
13>Small form factor.
14>Award winning design. (Cypress Design contest 2002, U.S.A.)
15>Can be operated up to 6 hours on battery backed up power supply.
16>Possible to connect to free-field Amplifier via separate junction box.

Packing List :
1> TAM 25 Audiometer.
2> S.M.P.S based battery backed up power supply.
3> HD-01 Headphones standard. (Optional TDH 39/49 can be ordered separately).
4> Oticon A20 Bone conductor standard. (Optional RadioEar B71 Bone conductor can be ordered separately.)
5> USB cable for computer connection.
6> External microphone with lapel clip.
7> CD containing TAM - Control software.
8> Patient Response Switch
9> Operating Manual.
10>Carry Case.

Triveni TAM 500M-E Audiometer

Features and Specifications :
1> FIRST TIME IN INDIA New Generation D.S.P Technology.
2> Capacitive touch sensitive keys (Just like Apple IPOD)
3> Very accurate frequency and threshold generation.
4> Completely click less interrupt.
5> Special Tests: -
1> Warble Tone
2> S.I.S.I.
3> T.D.
4> SAL.
5> ABLB.
6> Auto Threshold.
6> In Speech Audiometery TAM 500M-E can show horizontal bar and frequency spectrum of the incoming speech.
7> Out put mode can be Air conduction LEFT, RIGHT, LEFT+RIGHT. Bone conduction LEFT, RIGHT. Free field LEFT, RIGHT, LEFT + RIGHT.
8> Three selectable filter setting for Speech Audiometery.
9> +10dB key.
10>Dedicated Pulse Tone key.
11>Masking: - Wide, Narrow & Speech band noise.
12>Dedicated L-R toggle key.
13>Ability to store up to 500 Audiograms in internal memory. These audiograms can be downloaded to P.C using the provided software.
14>Bone conduction:- 125(40), 250Hz(50dB), 500Hz(70dB), 750Hz(70dB), 1Khz(70dB), 1.5Khz(70dB), 2Khz(70dB), 3Khz(70dB), 4Khz(70dB), 6Khz(70dB).
15>Air conduction:- 125(80dB), 250Hz(90dB), 500Hz(120dB), 750Hz(120dB), 1Khz(120dB), 1.5Khz(120dB), 2Khz(120dB), 3Khz(120dB), 4Khz(120dB), 6Khz(100dB), 8Khz(100dB).
16>Complete digital calibration.
17>Can be connected to a computer via USB port.
18> PC software provided free of cost in standard packing.
19> Can be connected to a Free-Field Amplifier.
20>Operates from 50/60Hz 90v to 270v AC supply

Packing List :
1> TAM 500M-E Audiometer.
2> HD-01 headphones optional TDH 49 Headphones.
3> RadioEar B71 or Oticon A20 Bone conductor.
4> USB cable for computer connection.
5> External microphone with lapel clip.
6> CD containing TAM - Control software.
7> Patient Response Switch
8> Operating Manual.
9> Carry Case.

Audiomini Audiometer

Features :
* 2 Channels
* AC
* BC
* MASKING (WHITE NOISE)
* LIVE VOICE
* Tone Decay Test
Accessories :
* TDH Headphone.
* Radioear B71 Bone Vibrator.
* Patient Response Button.
* Carrying Case.

Audiolite Pro Audiometer

DIAGNOSTIC DIGITAL AUDIOMETER
MAKE: LABAT MODEL: AUDIOLITE PRO
Features :
* AC
* BC
* MASKING
* LIVE VOICE
* TDT
Standard Accessories :
* TDH 39 Headphone
* B71 bone vibrator
* PC SOFTWARE.

Audiolab + PRO Audiometer

Features :
* AC
* BC
* MASKING
* LIVE VOICE
* SISI
* ABLB
* TDT
Standard Accessories :
* Head phone TDH-39/49 or equivalant.
* Radio EAR B.71 Bone Vibrator.
* Patient Response Button.
* USB Cable.
* Software

TDH 39, Air conduction Headphone Complete set for audiometers

The Telephonics TDH39 headphones are used with the following audiometers
Headband: HB7. Transducer: TDH39. Cable length: 2 m. Plug type: 30º, 2x6.3 mm gold-plated mono jack.
Specifications:
Receiver Type: Dynamic, with metal diaphragm
Impedance: TDH-39P - 10 ohms
Frequency Response: 100 Hz to 8000 Hz
Continuous Power Rating: 300 mW at any single frequency in the 100 Hz to 8000 Hz range
Linearity: Linearity for power inputs from 0 to 400 mW
Sensitivity: TDH-39P - 108 dB + 4 dB SPL (reference: 0 dB=20 µPA) Output with1 mW watt input at 1 KHz
Distortion: Less than 1 percent

B71 Bone Transducer from RadioEar (150 Ohm) for the hearing aid audiometers

B71 Bone Transducer from RadioEar. Type: B71W, ROHS compliant. The long established benchmark of bone conduction performance. The B71 is handmade and hand assembled to consistently perform to an exacting standard. The B71W is identical in all aspects of the original B71 with regards to performance and materials except it does not contain lead. It was developed in response to RoHS directive 2011/65/EU.
Technical data:
* Impedance 150 ohms @ 1KHz
* Frequency Response: 250-4000 Hz
* Max Input Voltage: 20 dB re 1.0mW
* Biocompatibility: no biological effects as per ISO 10993-1:2009
* Weight: 24g (0.846 oz)
* Connector: receptacle for Type 31 plug
Package content: 1 bone transducer
Please note that the audiometer must be recalibrated when replacing the headphones.

Audiology HeadPhone Replacement Cables/ TDH 39 Cables for audiometer

Length: 1.8m, Impedance: 10Ω
Wire Color: Black.
Connection Cable for headphones TDH39 and DD45.
With 6.3 mm red and blue jack connectors.For use with the hearing aid Audiometers.